A Termite-Inspired, Seasonal Approach to Window-to-Wall Ratio Design for Thermal Comfort in Office Buildings in Nigeria's Temperate Dry Region

Authors

DOI:

https://doi.org/10.5281/zenodo.20783296

Keywords:

Biomimicry, Termite mound, Thermal comfort, Window to wall ratio

Abstract

It is common knowledge that buildings in tropical countries are often affected by thermal discomfort. As a result, different window sizes and positioning strategies have been explored to mitigate this issue. Consequently, many studies have been conducted to determine the optimal window-to-wall ratio (WWR), a critical factor influencing thermal comfort in tropical regions. For example, research has shown that buildings with a WWR above 20% do not provide comfortable temperatures in tropical climates. The International Energy Conservation Code (2012 IECC) recommends a different value of 30%, while a study conducted in Singapore’s temperate dry climate found the optimal WWR to be 24%. However, none of these studies achieved consistent thermal comfort indoors, primarily because they did not account for seasonal variations, instead applying their findings uniformly throughout the year. Recent studies suggest that the optimal WWR varies by season. For instance, a 25% WWR was found to be optimal during the dry season, while 35% was ideal for the wet season. Interestingly, termite mounds maintain a stable internal climate despite fluctuating external conditions, making them an excellent model for improving thermal comfort in buildings. Research has revealed that termite mounds employ adaptive WWR modulation, using 30% WWR in the wet season and 25% in the dry season for thermoregulation. This study investigates the impact of seasonal WWR adjustments (10%, 15%, 20%, 30%) on thermal comfort in Nigerian office buildings through simulation, addressing the gap in climate-responsive design. It compares the WWR strategies of termite mounds and human buildings by evaluating WWR performance during hot and cold seasons. A prototype building was simulated using SketchUp, Revit, and DesignBuilder on hypothetical sites in Abuja, free from surrounding structures and trees. The generated data were analyzed using MANOVA, bar charts, column charts, graphs, and tables, with a significance threshold of 0.05. The findings revealed that the optimum WWR in office buildings in temperate dry climate of Nigeria are 15% WWR in hot season and 20% in cold season, which inversely mirror termite mound strategies of 30% in hot season and 25% in cold season. While human buildings prioritize minimizing heat gain, termite mounds utilize controlled ventilation for passive cooling.

References

Adebayo, A. A., & Adeboye, O. A. (2020). Climate change impacts on thermal comfort in tropical Africa: A case study of Nigeria. Journal of Environmental Design, 15(3), 45-62.

Ahsan, T. (2009). Optimizing window-to-wall ratio for tropical high-rises in Singapore. Building and Environment, 44(8), 1658–1666.

Amanowicz, Ł. (2018). Overheating and energy demand in poorly designed office buildings: A

review. Energy and Buildings, 172, 398–410.

Ashrae. (2007). ANSI/ASHRAE Standard 90.1: Energy standard for buildings except low-rise residential buildings. American Society of Heating, Refrigerating and Air-Conditioning Engineers.

Ashrae. (2010). ANSI/ASHRAE Standard 90.1: Energy standard for buildings except low-rise residential buildings (Rev. ed.). American Society of Heating, Refrigerating and Air-Conditioning Engineers.

Ashrae. (2025). ANSI/ASHRAE Standard 55: Thermal environmental conditions for human occupancy. American Society of Heating, Refrigerating and Air-Conditioning Engineers.

Athienitis, A., Stylianou, M., & Candanedo, J. (2021). Seasonal optimization of window-to-wall ratio for Canadian buildings. Solar Energy, 220, 1035–1048.

Budhiyanto, A. (2017). Thermal performance of office buildings in tropical climates: The role of WWR. International Journal of Sustainable Design, 4(2), 112–125.

Building Energy Efficiency Code. (2017). Ministry of Power, Nigeria.

Goel, S., Athienitis, A., & Gaur, A. (2014). Balancing daylight and energy in mid-rise buildings: A WWR analysis. Energy Procedia, 57, 2116–2125.

Harmtia, T., & Magyarb, R. (2015). Orientation-based WWR optimization for office buildings. Architectural Science Review, 58(4), 301–315.

International Energy Conservation Code (IECC). (2012). International Code Council.

Kandar, M. Z., Yusoff, W. F. M., & Ahmad, M. H. (2011). Optimum window-to-wall ratio for

tropical daylighting and thermal comfort. Pertanika Journal of Science & Technology, 19(2), 339–350.

King, H., Ocko, S., & Mahadevan, L. (2015). Termite mounds as biomimetic models for passive

ventilation. Nature Communications, 6, 8794.

Korb, J., & Linsenmair, K. E. (2000). Ventilation of termite mounds: New results from West

Africa. Insectes Sociaux, 47(1), 92–94.

Liping, W., & Hien, W. N. (2007). The effects of WWR on thermal comfort in tropical high-

rises. Building and Environment, 42(9), 3325–3335.

Lomas, K., Watson, S., & Allinson, D. (2022). Seasonal WWR adaptation in UK passive

houses. Energy and Buildings, 254, 111567.

Makela, L., Williamson, T., & Makela, E. (2011). Comparative analysis of WWR standards in

energy codes. Journal of Building Performance Simulation, 4(3), 189–202.

Medhat, M., Hayran, Z., Fareed, A., & Aziz, S. (2016). Typological classification of office

buildings. Architectural Research Quarterly, 20(1), 45–60.

Musa M.A., (2021). Optimising a Framework of Passive Indoor Environmental Comfort

of Office Building in Temperate Dry Climate of Nigeria. Unpublishe PhD Thesis Department of Architecture, Ahmadu Bello University Zaria.

Musa M.A., (2023). Assessing the Effects of Building Spatial Layout on Window to

Wall Ratio in Temperate Dry Climate of Nigeria. Proceedings of the 5th Baskent International Congress on Multidisciplinary Studies, Baskent University Ankara Turkey, December, 21-22, 2023

Musa, M.A., Salisu, A.S., & Salihu, M.M. (2024). Framework for optimising daylighting

and passive indoor thermal comfort in single-banked office buildings in the temperate dry climate of Nigeria. Architecture Papers of the Faculty of Architecture and Design STU, 29, 15 - 23. DOI: 10.2478/alfa-2024-0008

Ocko, S. A., King, H., Andreen, D., Bardunias, P., Turner, J. S., Soar, R., & Mahadevan, L. (2017). Solar heat gain modulation in termite mounds. Science Advances, 3(5), e1600981.

Ogbonna, A. C., & Harris, D. J. (2008). Thermal comfort in sub-Saharan Africa: Field study in

Nigeria. Building and Environment, 43(12), 2109–2124.

Ogunsote, O. O., Prucnal-Ogunsote, B., & Adebayo, A. (2021). Climate-responsive design in

tropical Africa: Lessons from Nigeria. Journal of Green Building, 16(2), 145–164.

Parker, A., Turner, J. S., & Soar, R. (2021). Seasonal porosity modulation in termite

mounds. Journal of Experimental Biology, 224(8), jeb242180.

Rashid, M., Malik, S., & Ahmad, S. (2016). Optimizing WWR for energy efficiency in

Lahore. Pakistan Journal of Science, 68(1), 45–52.

Regius, G. (2021). Cross-section of a termite mound [Illustration]. In Biomimicry in

Architecture.

Shebl, S. (n.d.). Window-to-wall ratio optimization for Egyptian office buildings (Unpublished

manuscript). Cairo University.

Turner, J. S. (2001). On the mound of Macrotermes michaelseni as an organ of respiratory gas

exchange. Physiological and Biochemical Zoology, 74(6), 798–822.

Turner, J. S., & Soar, R. C. (2008). Beyond biomimicry: What termites can teach us about

building design. International Journal of Design & Nature, 3(1), 1–18.

Published

2026-06-21

How to Cite

MUSA, M. A. (2026). A Termite-Inspired, Seasonal Approach to Window-to-Wall Ratio Design for Thermal Comfort in Office Buildings in Nigeria’s Temperate Dry Region. ISPEC JOURNAL OF SCIENCE INSTITUTE, 5(1), 9–17. https://doi.org/10.5281/zenodo.20783296

Issue

Section

Articles